- Reliable KFR56 Quick Response, Standard Spray Fusible Link Sprinklers
Reliable KFR56 Quick Response, Standard Spray Fusible Link Sprinklers
https://projectshub.odoo.com/shop/reliable-kfr56-quick-response-standard-spray-fusible-link-sprinklers-286 https://projectshub.odoo.com/web/image/product.template/286/image_1920?unique=cb45370Product Description
Model KFR56 series sprinklers are standard spray, quick-response sprinklers with a fusible link operating element. The sprinklers are cULus Listed, FM Approved, VdS Approved, and CE Certified. See Table C for available finishes. All KFR56 sprinklers have a nominal K-factor of 5.6 (80 metric). Model KFR56 series sprinklers are available in Ordinary (165°F [74°C]) or Intermediate (212°F [100°C]) temperature classification. Model KFR56 Pendent sprinklers are available with Model F1, Model F2, or Model FP recessed escutcheons.
Application
Model KFR56 series sprinklers are listed and approved for installation in accordance with NFPA 13 and FM Loss Prevention Data Sheets. Follow requirements of NFPA 13 for Quick-response Standard Spray Sprinklers when installing Model KFR56 series sprinklers. FM Approvals classifies Model KFR56 sprinklers as K5.6 QR Non-storage and K5.6 QR In-rack Storage sprinklers.
Installation
Model KFR56 series sprinklers must be installed in accordance with the requirements of NFPA 13 or FM Property Loss Prevention Data Sheets. The Model F1, F2, and FP escutcheons are the only recessed escutcheons listed and approved for use with Model KFR56 Pendent sprinklers. The use of any other recessed escutcheon will void all approvals and warranties. Do not install Model FP escutcheons in ceilings that are positively pressurized with respect to the occupied space below. Use only the Model W2 sprinkler wrench for installing Model KFR56 series pendent, upright, and horizontal sidewall sprinklers, and use the Model W1 or W4 wrench for installing Model KFR56 series recessed pendent, conical concealed pendent (CCP), and recessed horizontal sidewall sprinklers. The use of wrenches other than those specified may damage these sprinklers. Recommended installation torque is 14-20 ft-lbs (19 – 27 N.m). Do not tighten sprinklers over the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or impairment of the sprinklers.
Listings & Approvals
Listed by Underwriters Laboratories, Inc. and UL Certified
for Canada (cULus)
• Sprinklers, Automatic and Open (VNIV)
FM Approved (FM)
• K5.6 QR Non-storage
• K5.6 QR In-rack Storage
VdS Approved and CE Certified to EN12259
UKCA: 0832-UKCA-CPR-S5073, -5074, -5075
Model KFR Series Sprinkler Summary
Sprinkler Model |
Orientation |
Listing or Approval |
Max. Working |
Sprinkler |
KFR56 Pendent |
Pendent |
cULus |
250 (17.2) |
RA3614 |
| ||||
KFR56 Upright |
Upright |
cULus |
250 (17.2) |
RA3624 |
|
|
|||
KFR56 HSW |
HSW |
cULus |
250 (17.2) |
RA3634 |
|
|
|||
For more details and further reading, refer to the Attachments.